Electric Heating Cable & Mats | Roof & Gutter Deicing, Pipe Heat Trace Freeze Protection, Floor Warming, Embedded or Surface Mounted Snow Melting
Mor Electric Heating is one the largest distributors in the USA of Roof & Gutter Heating Cable and Pipe Heat Trace. We typically have over 35,000 feet of heating cable in stock. We even have Brian, a.k.a. "Heating Cable Guy" on staff (he is our most experienced heat trace salesman.) We have Contractors who are amazed at how excellent the experience with Brian is. His direct number is 1-616-647-5272 or use Ext. 5272. His e-mail is brian@morelectricheating.com.
Brian leads a team of qualified heat trace salesmen who are highly trained on heating cable and controls. All of our salesmen can quickly understand your roof, floor or pipe layout and decisively recommend the best way to handle your freeze protection or heating problem:
Art, 616-647-5271, art@morelectricheating.com
Bob, 616-647-5273, bob@morelectricheating.com
Brian, 616-647-5272, brian@morelectricheating.com
Philip, 616-647-5275, philip@morelectricheating.com
Combine that with our high stock levels and there is no reason to call anyone else! We are a distributor for most of the manufacturers such as NuHeat, EasyHeat, Danfoss, Wrap-On, King Electric, PowerTech, ETI, ASE, Calorique, Raychem, Briskheat, Proline, WarmlyYours, Warmup and Chromalox.
- Roof & Gutter Deicing Cable
- Pipe Heat Trace Freeze Protection. Electric Heating Cable
- Floor Warming Mats/Cables
- Concrete or Asphalt Embedded Electric Snow Melting Mats or Cable heats the surface above freezing to melt snow or ice
- Soil and Ground Electric Heaters and Cable. Gro-Quick, Soil Warming, Thermostatically controlled heat, Ground Thawing, Thermostats
- Surface Mounted Electric Snow Melting Mats & Stair Treads
- Thermal Storage Constant Watt Radiant Heating Cable and Mats take advantage of discounted overnight electricity rates
- Tapes (Adhesive)
- Controls for Heating Cable. Roof & Gutter Ice Melting Controls, Freeze Protection Pipe Trace Controls
- GFPE-8-277-30-4X 8 Circuit Control PanelDelta-Therm GFPE Series Relay Power Control Contactor Panel - Eight 2 pole relays rated at 30A - Each circuit has Ground Fault Circuit Protection of Equipment to 30mA - NEMA 4X Enclosure - 30"H x 24"W x 7"D
DELTATHERM855301006035
- GFPE-8-480-30-01 8 Circuit Control PanelDelta-Therm GFPE Series Relay Power Control Contactor Panel - Eight 2 pole relays rated at 30A - Each circuit has Ground Fault Circuit Protection of Equipment to 30mA - NEMA 1 Enclosure - 30"H x 24"W x 7"D
DELTATHERM855301006400
- GFPE-8-480-30-4X 8 Circuit Control PanelDelta-Therm GFPE Series Relay Power Control Contactor Panel - Eight 2 pole relays rated at 30A - Each circuit has Ground Fault Circuit Protection of Equipment to 30mA - NEMA 4X Enclosure - 30"H x 24"W x 7"D
DELTATHERM855301006042
- GPT-130 Heat Trace ControlETI (Environmental Technology Inc.) Tracon Point Microprocessor–Based Heat–Trace Temperature Controller Thermostat - Built in 30 amp relay with a 30mA GFEP - Operates heaters at temperature setpoints from -99.9F to 999F
ETI25170
- GVG-325-10 Standing Seam Saddle ClipRadiant Solutions Company Box of 10 Anodized Black Aluminum Clips - Includes 22 self-tapping hex head screws, can be used in conjunction with MKS-1022-2 butyl pads for permanent water-tight seal around fasteners, for use on 3/8" standing seams
RADIANTSOLUTIONS10025
- GVG-50-10 Standing Seam Saddle ClipRadiant Solutions Company Box of 10 Anodized Black Aluminum Clips - Includes 22 self-tapping hex head screws, can be used in conjunction with MKS-1022-2 butyl pads for permanent water-tight seal around fasteners, for use on 1/2" standing seams
RADIANTSOLUTIONS10026
- GVG-625-10 Standing Seam Saddle ClipRadiant Solutions Company Box of 10 Anodized Black Aluminum Clips - Includes 22 self-tapping hex head screws, can be used in conjunction with MKS-1022-2 butyl pads for permanent water-tight seal around fasteners, for use on 5/8" standing seams
RADIANTSOLUTIONS10027
- H622 Sold by Foot 240V WinterGard WetRaychem (nVent) WinterGard Wet 6 watts per Foot Self-Regulating Heat Cable - 240 Volt - *** Sold by the foot and cut to length. This is a custom order which cannot be cancelled or returned. ***
RAYCHEM10150
- HARD-SPACER-GALV-25MM-25MRaychem (nVent) Part #: SPACERGALV - Galvanized steel pre-punch strapping - 25 m roll
RAYCHEM715629006998
- HARD-SPACER-SS-25MM-25MRaychem (nVent) Part #: 107826-000 - Stainless steel pre-punched strapping - 25 m roll
RAYCHEM715629007001
- HOME AC0056 Touchscreen ThermostatNuheat Programmable 120/240V Dual-Voltage Thermostat - 3.5" 320x480 pixel color Screen - 7-day programmability - Built-in Class A GFCI - Compatible with any electric floor heating system using a 10K Ohm sensor-incl.sensor-15A - Part #: AC0056
NUHEAT10296
- HSC-24 Pavement Sensor/200 Feet of CableETI (Environmental Technology Inc.) Snow Switch Automatic 24 Volt Pavement-Mounted Snow/Ice Switch Sensor (requires 23832 Housing) - Includes 200 Feet of Hookup Cable - Snow & ice melting at pavement temperatures below 38F while moisture is present
ETI25625
- HW1125 120 Vac cut to-order purple 125FEasyHeat 120 Vac, cut to-order, purple, 125 deg F - Commercial Hot Water Pipe Temperature Maintenance - Self-Regulating - UPC Code: 013627006027 - *** Sold by the foot and cut to length. This is a custom order which cannot be cancelled or returned ***
EASY013627006027
- HW8105 208 Vac cut to-order blue 105FEasyHeat 208 Vac, cut to-order, blue, 105 deg F - Commercial Hot Water Pipe Temperature Maintenance - Self-Regulating - UPC Code: 013627005990 - *** Sold by the foot and cut to length. This is a custom order which cannot be cancelled or returned ***
EASY013627005990
- HW8115 208 Vac cut to-order green 115FEasyHeat 208 Vac, cut to-order, green, 115 deg F - Commercial Hot Water Pipe Temperature Maintenance - Self-Regulating - UPC Code: 013627006003 - *** Sold by the foot and cut to length. This is a custom order which cannot be cancelled or returned ***
EASY013627006003
- HW8125 208 Vac cut to-order yellow 125FEasyHeat 208 Vac, cut to-order, yellow, 125 deg F - Commercial Hot Water Pipe Temperature Maintenance - Self-Regulating - UPC Code: 013624005983 - *** Sold by the foot and cut to length. This is a custom order which cannot be cancelled or returned ***
EASY013624005983
- HW8140 208 Vac cut to-order red 140FEasyHeat 208 Vac, cut to-order, red, 140 deg F - Commercial Hot Water Pipe Temperature Maintenance - Self-Regulating - UPC Code: 013627006010 - *** Sold by the foot and cut to length. This is a custom order which cannot be cancelled or returned ***
EASY013627006010
- IDC-GPA-325-05 5 Each 3/8" Roof ClipsRadiant Solutions Company GripClip Model 325 - 5 Piece Box of 0.325"H Shingle Gripping Roof Clips for Self-Reg. Roof & Gutter De-Icing Heat Trace Cable - Black Color Anodized AL5052 Aluminum - Use with most common asphalt shingles up to 3/8" thickness
GRIPCLIP10005
- IDC-GPA-325-25 25 Each 3/8" Roof ClipsRadiant Solutions Company GripClip Model 325 - 25 Piece Box of 0.325"H Shingle Gripping Roof Clips for Self-Reg. Roof & Gutter De-Icing Heat Trace Cable - Black Color Anodized AL5052 Aluminum - Use with most common asphalt shingles up to 3/8" thickness
GRIPCLIP10001
- IDC-GPA-625-25 25 Each 5/8" Roof ClipsRadiant Solutions Company GripClip Model 625 - 25 Piece Box of 0.625"H Shingle Gripping Roof Cable Clips for Self-Regulating Roof & Gutter De-Icing Heat Trace Cable - Black Color Anodized AL5052 Aluminum - For use with roof material 3/8"- 5/8" thickness
GRIPCLIP10003
- IDC-GPA-875-25 25 Each 3/4" Roof ClipsRadiant Solutions Company GripClip Model 875 - 25 Piece Box of 0.875"H Shingle Gripping Roof Clips for Self-Reg. Roof & Gutter De-Icing Heat Trace Cable - Black Color Anodized AL5052 Aluminum - For use with roof material 1/2"- 3/4" thickness
GRIPCLIP10004
- IDP-100-C-01 Copper Slate/Cedar RoofClipRadiant Solutions Company Non-corrosive Copper Roof Clip for Self-Regulating Roof & Gutter De-Icing Heat Cable - 16" x 2" - 1 Piece - Clips slide under slate & cedar shakes & hook on existing fasteners
RADIANTSOLUTIONS10006
- IDP-113-25 25 Each Nail-On Roof ClipsRadiant Solutions Company 25 Piece Box of Standard Nail-On Roof Clips, Anodized Black Aluminum, 25 Pack, includes enhanced radius to improve cradles embrace of SR heat cable, can be used in conjuction with optional MKS-1022-1 butyl pads
RADIANTSOLUTIONS10014
- IDP-113-50 50 Each Nail-On Roof ClipsRadiant Solutions Company 50 Piece Box of Standard Nail-On Roof Clips, Anodized Black Aluminum, 25 Pack, includes enhanced radius to improve cradles embrace of SR heat cable, can be used in conjuction with optional MKS-1022-1 butyl pads
RADIANTSOLUTIONS10015
- IDP-115-01 1 Downspout Hanger & Zip TiesRadiant Solutions Company Downspout Hanger with 4 UV Resistant Cable Ties, Used to protect SR cable against damage from sharp points and edges in gutters and other locations
RADIANTSOLUTIONS10016
- IDP-S5S-05 5 Pack Roof Mounting BaseRadiant Solutions Company 5 Pack Bag of Standing Seam Roof Clamps - Mounting Base for Standing Seam Metal Roofs - Requires S-5 SR Clip attached to this base to secure heating cable
RADIANTSOLUTIONS10013
- IDP-S5S-30 30 Pack Roof Mounting BaseRadiant Solutions Company S5S Standing seam roof clamp - 30 Pack Box of Standing Seam Roof Clamps - Mounting Base for Standing Seam Metal Roofs - Requires S-5 SR Clip attached to this base to secure heating cable
RADIANTSOLUTIONS10017
-
- Install Pro Alarm AC0200 Fault DetectorNuheat Electrical Fault Indicator ensures a correct installation. Hear and see if the cable or mat has been damaged during installation - 9-volt battery included - Part #: AC0200
NUHEAT620713031063
- ITC1-000 Heat Trace Control 1 CircuitChromalox Digital Heat Trace Controller - 100-277VAC Rating - 40 Amp Rating with GFEP Protection - Operating Temperature: -40 F to 104 F
CHROM316101