ADKS-150 30 Foot 120V 150W Heat Cable

SKU:

EASY10004

Manufacturer: 

Easy Heat

More Information
Best Seller/Typically In Stock? Yes
Manufacturer Easy Heat
Manufacturer Part Number ADKS-150
UPC/GTIN Code 013627109704
Color Black
Cable Construction Constant Wattage
Voltage 120 Volt
Wattage 150 Watt
Amperage 1.3 Amp
Length of Product 30 Feet
Watt/Foot 5 Watt/Ft
Heat Trace Termination Type Pre Terminated Heat Trace
Heat Trace Type Roof and Gutter Heat Trace
Product Condition New

Features of Easy Heat ADKS-150


The Easy Heat ADKS series roof and gutter de-icing heat trace cable is an easy to use, pre-terminated, constant wattage heat trace designed to prevent costly ice damage by preventing ice dam formation and promoting the free flow of melt water through gutters and downspouts. This product is for the sole intended use of preventing ice dams from forming on inclined roofs with tab shingles, in gutters and in downspouts. This roof de-icing cable is not intended for use as a snow-melting system to clear roof of ice and snow. Never install on a flat roof. Never install on combustible materials. Not suitable for use on metal roofs.

  • The ADKS kit includes a de-icing cable with a 6 foot long cold section and plug, roof clips, and cable spacers.

Eliminate damage caused by ice dams.


Even in below freezing weather, snow on the roof will often thaw because of heat from the sun and heat loss from the house through the roof. As this melted snow reaches the roof overhang it refreezes. Here there is no heat loss so the roof surface is much colder. As this melted snow refreezes again and again on the roof overhang, an ice dam is formed. Soon water backs up under shingles, and leaks into the house. ADKS roof de-icing cable prevents water and ice damage by providing a clear path for melting water. It keeps roof edges, gutters and downspouts ice-free.

When designing a roof and gutter de-icing system, it is important to know that the Easy Heat ADKS heat trace is not intended to completely eliminate snow and ice from the roof. It is simply designed to allow for the free flow of melt water off of the roof edge, down the gutter and downspouts, and finally away from the foundation of the structure. The heat trace cable length should be selected to allow for the cable to serpentine along the roof edge, drop down into and then down the gutter, and then finally exit through the downspout. This will allow for a complete path for the melt water to flow which will eliminate the costly ice dams from forming on the roof edge.