Best Seller/Typically In Stock? | Yes |
---|---|
Manufacturer | Danfoss |
Manufacturer Part Number | 088L3505 |
UPC/GTIN Code | 5703466162088 |
Color | Black |
Cable Construction | Constant Wattage |
Voltage | 120 Volt |
Wattage | 535 Watt |
Amperage | 4.5 Amp |
Length of Product | 120 Feet |
Watt/Foot | 4.5 Watt/Ft |
Heat Trace Termination Type | Pre Terminated Heat Trace |
Heat Trace Type | Roof and Gutter Heat Trace |
Product Condition | New |
Features of Danfoss 088L3505 RX 120FT 120 Volt 535 Watt Roof and Gutter Deicing Cable
Danfoss RX Series constant wattage heating cables are designed to provide the protection needed to prevent ice dams and snow accumulation from damaging buildings and gutters. The RX cables ensure maximum energy efficiency and are can be used with metal or asphalt roofing.
- Voltage: 120 Volt
- Output: 5 Watt/Ft
- Cable Length: 120 Ft
- Power Lead Length: 6 Ft
- Cable Construction: Twin Conductor, Constant Wattage
- Cable Diameter: 0.25 Inch
- Minimum Bending Radius: 1.5 Inch
- Conductor Insulation: FEP Teflon / XLPE Cross Linked Polyethylene
- Outer Insulation: PVC
- Max Temperature: 220°F (105°C)
- Min Installation Temperature: 40°F (5°C)
- Professional Grade Cable and AC Plug
- UV Rated to withstand the harshest conditions
Additional Application Information
It is important that this equipment is installed only by qualified persons familiar with the proper sizing, installation, and operation of electric roof and gutter heating systems. Working on a ladder and roof can be dangerous; care must be observed. The cables are designed for outdoor applications only.
- Do Not Install RX Cable Inside the Roof or Walls of The Building.
- Never Cut the Black Heating Cable.
- Do Not Use an Extension Cord.
- Do Not Install RX Cable Such That Two Black Heating Cables Touch, Overlap or Cross Each Other.
- Never Energize Coiled Cable.
- Do Not Use with Wooden Shingles.